江智浩
江智浩
简介
项目
动态
论文
团队
联系
浅色
深色
自动
中文 (简体)
中文 (简体)
English
MedicalDevice
Synthesizing Stealthy Reprogramming Attacks on Cardiac Devices
An Implantable Cardioverter Defibrillator (ICD) is a medical device used for the detection of potentially fatal cardiac arrhythmias and …
N Paoletti
,
江智浩
,
MA Islam
,
H Abbas
,
R Mangharam
,
S Lin
,
Z Gruber
,
SA Smolka
引用
项目
DOI
High-level modeling for computer-aided clinical trials of medical devices
Medical devices like the Implantable Cardioverter Defibrillator (ICD) are life-critical systems. Malfunctions of the device can cause …
H Abbas
,
江智浩
,
KJ Jang
,
M Beccani
,
J Liang
,
R Mangharam
引用
项目
DOI
In silico pre clinical trials for implantable cardioverter defibrillators
This paper presents in-silico pre-clinical trials for implantable cardioverter defibrillators using large cohorts of synthetic patients …
江智浩
,
H Abbas
,
K Jang
,
M Beccani
,
J Liang
,
S Dixit
,
R Mangharam
引用
项目
DOI
Towards Model Checking of Implantable Cardioverter Defibrillators
Ventricular Fibrillation is a disorganized electrical excitation of the heart that results in inadequate blood flow to the body. It …
H Abbas
,
KJ Jang
,
江智浩
,
R Mangharam
引用
项目
项目
DOI
The Challenges of High-Confidence Medical Device Software
Bringing new safety-critical medical devices to market faces several major challenges, but modeling and formal methods can facilitate …
江智浩
,
H Abbas
,
KJ Jang
,
R Mangharam
引用
DOI
High-Confidence Medical Device Software Development
This survey examines the challenges of developing high-confidence software for implantable medical devices, especially under …
江智浩
,
R Mangharam
引用
项目
DOI
Modeling cardiac pacemaker malfunctions with the Virtual Heart Model
This work studies pacemaker malfunctions caused by imperfect sensing assumptions, such as lead displacement or cross-chamber …
江智浩
,
R Mangharam
引用
项目
DOI
Cyber Physical Modeling of Implantable Cardiac Medical Devices
The design of bug-free and safe medical device software is challenging, especially in complex implantable devices that control and …
江智浩
,
M Pajic
,
R Mangharam
引用
项目
项目
DOI
Model Based Closed-Loop Testing of Implantable Pacemakers
The increasing complexity of software in implantable medical devices such as cardiac pacemakers and defibrillators accounts for over …
江智浩
,
M Pajic
,
R Mangharam
引用
项目
DOI
Using the Virtual Heart Model to validate the mode switch pacemaker operation
This paper uses a timed-automata Virtual Heart Model to validate complex mode-switch pacemaker behavior in closed loop. Through …
江智浩
,
AT Connolly
,
R Mangharam
引用
项目
DOI
引用
×